<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">vetpatol</journal-id><journal-title-group><journal-title xml:lang="en">Russian Journal of Veterinary Pathology</journal-title><trans-title-group xml:lang="ru"><trans-title>Ветеринарная патология</trans-title></trans-title-group></journal-title-group><issn pub-type="epub">2949-4826</issn><publisher><publisher-name>Don State Technical University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.23947/2949-4826-2026-25-2-25-33</article-id><article-id custom-type="edn" pub-id-type="custom">RCHCEF</article-id><article-id custom-type="elpub" pub-id-type="custom">vetpatol-2146</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Animal pathology, morphology, physiology, pharmacology and toxicology</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Патология животных, морфология, физиология, фармакология и токсикология</subject></subj-group></article-categories><title-group><article-title>Optimization of General Anesthesia Monitoring Methods Used in Laboratory Animals during Development and Experimental Study of Veterinary Drugs</article-title><trans-title-group xml:lang="ru"><trans-title>Оптимизация методов контроля общей анестезии лабораторных животных при разработке и экспериментальном изучении ветеринарных препаратов</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-9350-7588</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шебеко</surname><given-names>С. К.</given-names></name><name name-style="western" xml:lang="en"><surname>Shebeko</surname><given-names>S. K.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Шебеко Сергей Константинович, доктор фармацевтических наук, профессор, заведующий кафедрой «Биотехнические и медицинские системы и технологии»</p><p>344003, г. Ростов-на-Дону, пл. Гагарина, 1</p></bio><bio xml:lang="en"><p>Sergei K. Shebeko, Dr.Sci.(Pharmacy), Professor, Head of the Department of Biotechnical and Medical Systems and Technologies</p><p>1, Gagarin Square, Rostov-on-Don, 344003</p></bio><email xlink:type="simple">shebeko_sk@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Донской государственный технический университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Don State Technical University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>23</day><month>07</month><year>2026</year></pub-date><volume>25</volume><issue>2</issue><fpage>25</fpage><lpage>33</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Shebeko S.K., 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">Шебеко С.К.</copyright-holder><copyright-holder xml:lang="en">Shebeko S.K.</copyright-holder><license license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.vetpat.ru/jour/article/view/2146">https://www.vetpat.ru/jour/article/view/2146</self-uri><abstract><p>Introduction. Giving general anesthesia to animals is an important element of experimental research during the development and study of new veterinary drugs. Due to specific nature of general anesthesia and the need to use the potent sedatives and hypnotics, it has always been posing a risk to laboratory animals. In the frame of present-day veterinary research, the problem of proficient monitoring of anesthesia is extremely relevant, especially with regard to research involving laboratory rodents. The aim of the study is to develop and optimize laboratory monitoring methods of general anesthesia in animals during experimental studies of new veterinary drugs.Materials and Methods. The study was conducted at the research laboratory of the Institute of Living Systems, DSTU, from January to May 2024. The experiment involved 20 Wistar rats of both sexes weighing 300–400 g that were subjected to inhalation anesthesia with isoflurane, using an RWD R520 anesthesia machine. The laboratory monitoring protocols were developed based on the electroencephalography (EEG), electrocardiography (ECG), respiratory rate, blood pressure, and body temperature parameters. The condition of animal organs and systems was assessed by means of biochemical blood and urine tests, as well as excretory function tests.Results. An inhalation chamber connected to an anesthesia machine was designed for the study in rats. It allowed labor-atory monitoring of animals’ condition during inhalation anesthesia by electrophysiological and functional methods. A trial mode of the chamber using 2.0% isoflurane gas supply, at a flow rate of 2.0 l/min, and a withdrawal rate of 8.0 l/min had proved to be the optimal protocol for administering general anesthesia to laboratory rats. Electrophysiological, biochemical, and functional parameters demonstrated high tolerability of the anesthesia protocol used.Discussion and Conclusion. The development proposed by the authors optimizes laboratory monitoring in animals during general anesthesia, contributes to improvement of quality of experimental research results, facilitates the work of re-searchers, and can be used during the development of new veterinary drugs.</p></abstract><trans-abstract xml:lang="ru"><p>Введение. Общая анестезия животных является важным элементом экспериментальных исследований при разработке и изучении новых ветеринарных препаратов. В силу своей специфики, необходимости применения сильнодействующих седативных и гипнотических средств, анестезия всегда представляет собой риск для лабораторных животных. В настоящее время в ветеринарных исследованиях остро стоит проблема грамотного анестезиологического сопровождения, особенно при работе с лабораторными грызунами. Цель данного исследования — разработка и оптимизация методов лабораторного контроля общей анестезии животных при проведении экспериментальных исследований новых ветеринарных препаратов.Материалы и методы. Исследование проведено на базе научно-исследовательской лаборатории Института живых систем ДГТУ в период с января по май 2024 г. В эксперименте участвовало 20 крыс линии Wistar обоих полов массой 300–400 г, которых подвергали общей ингаляционной анестезии с использованием изофлурана и наркозного аппарата RWD R520. Протоколы лабораторного контроля разрабатывали на основе показателей электроэнцефалографии, электрокардиографии, частоты дыхания, артериального давления и температуры тела. Оценку состояния органов и систем животных проводили с помощью биохимических исследований крови, мочи и показателей выделительной функции животных.Результаты исследования. В ходе исследований была сконструирована ингаляционная камера для крыс, подключаемая к наркозному аппарату, позволяющая проводить лабораторный контроль электрофизиологическими и функциональными методами в условиях ингаляционной анестезии. Апробация камеры при режиме подачи газа с концентрацией изофлурана 2,0 %, скоростью подачи 2,0 л/мин и отбора 8,0 л/мин, показала, что это оптимальный протокол осуществления общей анестезии у лабораторных крыс. Данные электрофизиологических, биохимических и функциональных параметров свидетельствовали о хорошей переносимости использованного анестезиологического протокола.Обсуждение и заключение. Предложенная авторская разработка оптимизирует лабораторный контроль животных при проведении общей анестезии, способствует повышению качества результатов экспериментальных исследований, облегчает работу ученых-исследователей и может быть использована при разработке новых ветеринарных препаратов.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>общая анестезия</kwd><kwd>лабораторный контроль</kwd><kwd>экспериментальные исследования</kwd><kwd>лабораторные крысы</kwd><kwd>ингаляционный наркоз</kwd><kwd>ингаляционная камера</kwd><kwd>электрофизиологические параметры</kwd></kwd-group><kwd-group xml:lang="en"><kwd>general anesthesia</kwd><kwd>laboratory monitoring</kwd><kwd>experimental studies</kwd><kwd>laboratory rats</kwd><kwd>inhalation anesthesia</kwd><kwd>inhalation chamber</kwd><kwd>electrophysiological parameters</kwd></kwd-group></article-meta></front><body><p>Introduction. General anesthesia in animals is an integral part not only of veterinary practice but also of experimental studies of veterinary drugs. Laboratory monitoring of anesthesia is an important factor for its successful implementation [<xref ref-type="bibr" rid="cit1">1</xref>]. Due to its specific nature and the need for potent sedatives and hypnotics, anesthesia evidently has always been posing a risk for laboratory animals, especially for young and elderly animal specimens and animals with induced pathologies [<xref ref-type="bibr" rid="cit2">2</xref>][<xref ref-type="bibr" rid="cit3">3</xref>][<xref ref-type="bibr" rid="cit4">4</xref>]. Complications resulting from general anesthesia manifest not only in deterioration of animal's physiological functions and the state of all life support systems, but also in exacerbation of the pathological process, which can even lead to death [<xref ref-type="bibr" rid="cit5">5</xref>].</p><p>According to statistics, adverse reaction to anesthesia is a quite widespread phenomenon in veterinary practice [<xref ref-type="bibr" rid="cit6">6</xref>]. Poor recovery from general anesthesia in dogs is observed in 29.1% of cases, with 55.5% of them requiring sedation to control behavior [<xref ref-type="bibr" rid="cit7">7</xref>]. In sick animals, anesthesia-related mortality is 3.6 times higher than this figure in the overall animal population (4.80% versus 1.35%) [<xref ref-type="bibr" rid="cit2">2</xref>], moreover, in sick dogs the probability of cardiac arrest caused by anesthesia is 23 times higher, and the probability of death is 24.5 times higher than in healthy animals [<xref ref-type="bibr" rid="cit8">8</xref>]. Post-operative mortality is of particular concern in sick animals. According to some data, it reaches 47% in dogs, 61% in cats and 64% in rabbits. In the overall animal population, rabbits are the most susceptible to anesthesia-and sedation-related mortality, with the risk of death being 8 times higher than that in dogs (1.39% versus 0.17%) [<xref ref-type="bibr" rid="cit9">9</xref>].</p><p>Currently, the problem of proficient monitoring anesthesia when working with animals, along with proper examination, and adherence to recommendations is acute, both in experimental research and in veterinary medicine [<xref ref-type="bibr" rid="cit10">10</xref>][<xref ref-type="bibr" rid="cit11">11</xref>]. This problem is especially relevant when working with small rodents, which are the main test systems in biomedical research, due to their small size and metabolic characteristics [<xref ref-type="bibr" rid="cit12">12</xref>]. The opportunities of Russian scientists in the field of experimental veterinary research are considerably limited due to limited access to modern technologies, medicinal products, and equipment, especially those used for monitoring general anesthesia in laboratory rodents. Therefore, improving approaches to administering general anesthesia and laboratory monitoring of the process in the frame of experimental studies is of scientific importance for improving animal safety.</p><p>The aim of the study is to develop and optimize the methods for monitoring general anesthesia in laboratory animals to improve the efficiency and safety of experimental studies of new veterinary drugs.</p><p>Materials and Methods. The study was conducted at the Pharmacology and Experimental Pathology Research Laboratory of the Institute of Living Systems, DSTU (Rostov-on-Don) from January to May 2024. Twenty Wistar rats of both sexes weighing 300–400 g were involved in the experiment. All animals were kept on a standard diet with free access to water in accordance with acting sanitary standards [<xref ref-type="bibr" rid="cit13">13</xref>].</p><p>The studies were conducted in compliance with the general principles of bioethics [<xref ref-type="bibr" rid="cit14">14</xref>] and Directive 2010/63/EU of the European Parliament and of the Council “On the Protection of Animals Used for Scientific Purposes” (Brussels, 2010) [<xref ref-type="bibr" rid="cit15">15</xref>]. All manipulations causing pain and suffering, and the withdrawal of animals from the experiment was conducted using adjusted dosage of anesthesia and analgesia [<xref ref-type="bibr" rid="cit16">16</xref>]. The protocol of the study was verified by the Local Independent Ethics Committee of DSTU (Resolution No. 4 of 09.10.2023).</p><p>General anesthesia of animals was performed using an RWD R520 anesthesia machine for animals (RWD Life Science, USA) and isoflurane (Laboratories Karizoo, S.A., Spain).</p><p>Using the KOKS-2 cardiorespiratory complex for small laboratory animals (Medical Computer Systems Ltd., Russian Federation), electrocardiography (ECG) was performed, and heart rate (HR) and respiratory rate (RR) were assessed [<xref ref-type="bibr" rid="cit17">17</xref>][<xref ref-type="bibr" rid="cit18">18</xref>]. Blood pressure (BP) was assessed by non-invasive plethysmometric method [<xref ref-type="bibr" rid="cit19">19</xref>] using the “Sistola” non-invasive blood pressure measurement system for rodents with the “Phlogiston” heating platform (Neirobiotiks LLC, Russian Federation). Brain activity intensity was assessed by electroencephalography (EEG) [<xref ref-type="bibr" rid="cit20">20</xref>] using the “Neiron-Spektr-1V" computerized electroencephalograph for veterinary medicine (Neirosoft LLC, Russian Federation). Animal body temperature (T) was measured using a Zamer-1 veterinary digital rectal thermometer (version 2 – rectal, Zamer LLC, Russian Federation). During laboratory observations, the animals’ pedal, swallowing, and pupillary reflexes were also assessed.</p><p>To assess the functional condition of the organs and systems of animals before and after anesthesia, a series of biochemical studies of blood and urine were performed. Blood was obtained from the caudal vein in an amount of up to 0.5 ml per draw. The glucose concentration in native blood was determined using a OneTouch Verio Reflect glucometer (LifeScan Europe GmbH, Switzerland). Creatinine content, aspartate aminotransferase (AST) and alanine aminotransferase (ALAT) activity were determined in blood serum using “Diacon-DS” kits and a SPECTROstar Nano spectrophotometer (BMG Labtech, Germany) [<xref ref-type="bibr" rid="cit21">21</xref>]. Urine was obtained using metabolic cages (OpenScience, Russian Federation) with a duration of collection for 2 hours. The creatinine content was also determined in urine, as well as the glomerular filtration rate (GFR) was calculated based on the endogenous creatinine clearance [<xref ref-type="bibr" rid="cit22">22</xref>].</p><p>The obtained results were processed using descriptive statistics methods, tested for normality using the Shapiro-Wilk test, and presented as the arithmetic mean ± standard error of the mean (M ± m). Statistical analysis of intergroup differences was performed using one-way analysis of variance (ANOVA) with Tukey's HSD post hoc test [<xref ref-type="bibr" rid="cit23">23</xref>]. Calculations were performed using IBM SPSS Statistics v. 22 (IBM Corp., USA) and MS Excel 2016 (Microsoft Corp., USA) software. Differences in figures were considered statistically significant at a probability level of p &lt; 0.05.</p><p>Results. Inhalation anesthesia is the preferred method of general anesthesia used in experimental studies in terms of efficacy and safety, as it enables complete control over animal's condition through a combination of two key parameters: the concentration of the inhalation anesthetic and the rate of gas mixture flow. This method not only allows quick putting an animal in a state of pharmacological hypnosis but also its immediate recovery after cessation of gas delivery, practically without adverse consequences. Therefore, the study proposes improvement of laboratory monitoring techniques used specifically for this type of anesthesia.</p><p>Inhalational anesthetics, especially isoflurane, are known to pose a hazard to professionals who are constantly in contact with them during work. The standard masks supplied with the RWD R520 animal anesthesia machine are not hermetically sealed and are prone to gas leakage. To solve the problem, a sealed inhalation chamber for rats that enabled laboratory monitoring based on measuring the electrophysiological parameters was designed. The design of the chamber had been developed to ensure enough space to place EEG electrodes on the animal’s scalp as well as the respiratory sensor of the cardiorespiratory system with a minimal working volume of a gas mixture required. At the same time, there remained the possibility to place ECG sensors on the animal’s torso, a blood pressure cuff on the tail, and a rectal thermometer in the anus. Implementation of all the above-mentioned monitoring elements was possible only using a chamber, where the animal’s head was placed, leaving the rest of the body free. The standard inhalation anesthesia induction chambers are not suitable for this purpose.</p><p>The chamber was made of transparent polycarbonate with external dimensions of 100 x 100 x 60 mm and an internal volume of 500 cm³ (Fig. 1). A nozzle adhering to DIN standard with an internal diameter of 6 mm was used to deliver the gas mixture to the chamber, and a nozzle adhering to 22M standard with an internal diameter of 18 mm was used to remove the waste gas. These nozzles were positioned opposite each other to ensure a unidirectional gas flow, so that it could reach the inlets of the animal’s respiratory tract. The 1:3 ratio of inlet to outlet nozzle cross-sections ensured the flow of the gas mixture from the entry to evacuation point. Six animals were involved at the stage of inhalation chamber design and assembly.</p><fig id="fig-1"><caption><p>Fig. 1. A prototype of an inhalation chamber for general anesthesia in rats</p></caption><graphic xlink:href="vetpatol-25-2-g001.jpeg"><uri content-type="original_file">https://cdn.elpub.ru/assets/journals/vetpatol/2026/2/4ZT7otPQNfInRzb6ykGVCpijvEd7N4WIAur57lu3.jpeg</uri></graphic></fig><p>To solve the problem, it was necessary not just design a chamber itself, develop the method of putting the upper part of the animal’s body into it, but also to invent the way of forced gas removal from the chamber using a gas evacuation device and replaceable gas filters supplied with the anesthesia machine. Such devices are designed to absorb and bind excess inhalational anesthetic, thereby ensuring operational safety. In the current experiment, two RWD Life Science gas evacuation apparatuses with the gas filter weighing function were used: R546-Pro with forced gas removal and R548 without it, with corresponding gas filters R510-31-6 and R510-31S-6.</p><p>During general anesthesia, the animal was exposed to isoflurane in the induction chamber. The animal was then placed on the experimental heating platform, fixed, and its head was placed in the inhalation chamber. EEG electrodes were attached, a respiration sensor was installed, and the ECG electrodes were applied. The inhalation chamber was then closed, and the gas mixture started to be delivered (Fig. 2). The animal’s tail was then placed on a “Phlogiston” heating platform, a blood pressure cuff was applied, and a rectal thermometer was inserted. The animal remained in this position throughout the general anesthesia procedure to enable laboratory monitoring, piloting this technique, and recording the respective physiological parameters. The resulting data were analysed for the efficacy of the proposed monitoring methods and safety of the tested general anesthesia protocol.</p><fig id="fig-2"><caption><p>Fig. 2. A Wistar rat monitored during inhalation anesthesia using the developed inhalation chamber</p></caption><graphic xlink:href="vetpatol-25-2-g002.jpeg"><uri content-type="original_file">https://cdn.elpub.ru/assets/journals/vetpatol/2026/2/Rc9Qd53XZCscIry4fRcOGWIieNMde7KM9X11RZU5.jpeg</uri></graphic></fig><p>During the study, two modes of anesthesia administration were used — using active and passive gas removal, whereas the concentration ratio and flow rate were adjusted to minimize the effect on the animal. During the adjustment process, we judged about the depth of anesthesia in rats by determining the stages based on the animal condition, the level of reflexes and physiological parameters.</p><p>As a result, two gas delivery modes were used:</p><p>1st mode: isoflurane concentration 2.0%, flow rate 2.0 l/min, removal rate 8.0 l/min;</p><p>2nd mode: isoflurane concentration 1.5%, flow rate 2.0 l/min, without forced gas removal.</p><p>With respect to these modes, two groups of seven animals were formed and exposed to general anesthesia with assessment of laboratory monitoring methods based on physiological parameters recorded.</p><p>During the study, electroencephalograms (EEG) were continuously recorded in the animals in the state of inhalation anesthesia (Fig. 3), and EEG indices were computed using the software (Table 1).</p><fig id="fig-3"><caption><p>Fig. 3 Example of an electroencephalogram of a rat in the state of general anesthesia</p></caption><graphic xlink:href="vetpatol-25-2-g003.jpeg"><uri content-type="original_file">https://cdn.elpub.ru/assets/journals/vetpatol/2026/2/0NhLx7Uy8RVLSk4PwrRCm0BVS4roETi02b6NvMbA.jpeg</uri></graphic></fig><table-wrap id="table-1"><caption><p>Table 1</p><p>Electroencephalogram indices in rats in condition of general anesthesia 30 minutes after induction</p><p>Note: * – differences are significant relative to animals of the 1st group (p&lt;0.05).</p></caption><table><tbody><tr><td>EEG indices</td><td>1st group (n=7)</td><td>2nd group (n=7)</td></tr><tr><td>Maximum amplitude, µV</td><td>130.2±13.7</td><td>112.7±11.0</td></tr><tr><td>Mean amplitude, µV</td><td>19.3±2.2</td><td>15.8±1.6</td></tr><tr><td>Delta rhythm, μV</td><td>45.6±4.5</td><td>58.7±5.5</td></tr><tr><td>Theta rhythm, μV</td><td>33.5±3.5</td><td>37.2±4.0</td></tr><tr><td>Alpha rhythm, μV</td><td>31.4±3.2</td><td>20.3±2.7*</td></tr><tr><td>Beta-LF rhythm, μV</td><td>11.7±1.5</td><td>10.2±1.3</td></tr><tr><td>Beta-HF rhythm, μV</td><td>10.7±1.2</td><td>5.9±1.0*</td></tr></tbody></table></table-wrap><p>The EEG was analysed by the general indices of maximum and mean amplitudes, as well as the indices of mean amplitudes of five main rhythms: delta rhythm with a frequency of 0.5–3.0 Hz, theta rhythm (4.0–6.0 Hz), alpha rhythm (8.0–13.0 Hz), low frequencies of the beta band (13.0–18.0 Hz) and high frequencies of the beta band (18.0-32.0 Hz) [<xref ref-type="bibr" rid="cit20">20</xref>]. Analysis of the EEG spectral amplitudes makes it possible to determine the predominant type of EEG rhythm and, based on this, draw a conclusion about the degree of animal immersion in anesthesia, weakening the hypnotic effect of anesthetics, or, conversely, excessive depth of anesthesia with the risk of a lethal outcome, as well as to record the moment of agonal phase or clinical death development.</p><p>The results presented in Table 1 indicate a greater depth of anesthesia in rats anesthetized with the second mode of gas mixture delivery compared to the first group. This is confirmed by a non-significant decrease in the maximum and mean EEG amplitudes, growing predominance of the delta rhythm (p&gt;0.05), and a significant decrease in the amplitudes of the alpha rhythm and beta-high-frequency rhythm (p&lt;0.05).</p><p>Moreover, during general anesthesia, cardiorespiratory parameters were recorded in rats (Fig. 4), as well as blood pressure and body temperature 10 minutes after induction of anesthesia and after 30 minutes (before the end of the experiment). The data are presented in Table 2.</p><fig id="fig-4"><caption><p>Fig 4. Example of recording the cardiorespiratory data in rats in the state of general anesthesia</p></caption><graphic xlink:href="vetpatol-25-2-g004.jpeg"><uri content-type="original_file">https://cdn.elpub.ru/assets/journals/vetpatol/2026/2/cTZMCEPDZ8rt2SFe4vNXZikdEQWGsqgJFX2T14l9.jpeg</uri></graphic></fig><table-wrap id="table-2"><caption><p>Table 2</p><p>The effect of the experimental modes of inhalation anesthesia on cardiorespiratory parameters and temperature in rats</p><p>Notes: *— differences are significant relative to the baseline data (p&lt;0.05);**— differences are significant relative to animals of the 1st group (p&lt;0.05).</p></caption><table><tbody><tr><td>Parameter studied</td><td>1st group (n=7)</td><td>2nd group (n=7)</td></tr><tr><td>10 min</td><td>30 min</td><td>10 min</td><td>30 min</td></tr><tr><td>HR, beats/min</td><td>225±12</td><td>215±10</td><td>222±13</td><td>181±11*/**</td></tr><tr><td>R wave voltage, mV</td><td>0.85±0.03</td><td>0.78±0.05</td><td>0.80±0.05</td><td>0.52±0.07*/**</td></tr><tr><td>RR, breaths/min</td><td>55±3</td><td>50±4</td><td>53±5</td><td>42±3*</td></tr><tr><td>BP, mmHg</td><td>systolic</td><td>121.2±4.4</td><td>115.1±3.5</td><td>119.7±3.8</td><td>99.4±2.3*/**</td></tr><tr><td>diastolic</td><td>78.1±2.8</td><td>75.6±2.5</td><td>79.2±3.0</td><td>71.3±3.3</td></tr><tr><td>mean</td><td>99.6±3.5</td><td>95.3±3.1</td><td>98.1±4.2</td><td>84.9±3.1*/**</td></tr><tr><td>T, °С</td><td>37.8±0.2</td><td>35.2±0.2*</td><td>37.5±0.3</td><td>33.1±0.5*/**</td></tr></tbody></table></table-wrap><p>The obtained results indicate that in animals exposed to general anesthesia using the second experimental mode, the significant decrease in heart rate (HR) by 18.5%, as well as decrease in the R wave voltage by 1.6 times, and respiratory rate (RR) by 20.7% (p &lt; 0.05) were observed. This pattern indicates a more pronounced suppression of cardiovascular and respiratory systems than in the first group (Table 2).</p><p>Moreover, in the second group, a significant decrease in systolic and mean blood pressure by 16.7% and 14.3%, respectively, was also observed (p &lt; 0.05). By the end of the experiment, body temperature in rats in this group significantly decreased to 33.1°C, which was statistically lower than in animals in the first group (p &lt; 0.05). This also indicates an impairment in the function of cardiovascular system and general depression of body functions, which was more typical for animals in the second mode of general anesthesia, and correlates with the previous data.</p><p>Additionally, a number of biochemical parameters, including the renal function indices, were assessed in animals before and after anesthesia, and are presented in Table 3.</p><table-wrap id="table-3"><caption><p>Table 3</p><p>Biochemical parameters and renal function indices in rats in the state of general anesthesia</p><p>Notes: * – differences are significant relative to the baseline data (p&lt;0.05);**– differences are significant relative to animals the 1st group (p&lt;0.05).</p></caption><table><tbody><tr><td>Parameter</td><td>1st group (n=7)</td><td>2nd group (n=7)</td></tr><tr><td>before anesthesia</td><td>after anesthesia</td><td>before anesthesia</td><td>after anesthesia</td></tr><tr><td>Blood glucose, mmol/l</td><td>4.61±0.18</td><td>4.24±0.17</td><td>4.80±0.19</td><td>3.76±0.19*/**</td></tr><tr><td>Blood creatinine, μmol/l</td><td>45.65±3.17</td><td>39.04±2.68</td><td>42.15±2.89</td><td>55.56±3.86*/**</td></tr><tr><td>AST, µkat/l</td><td>0.75±0.02</td><td>0.71±0.02</td><td>0.69±0.07</td><td>0.78±0.05</td></tr><tr><td>ALT, µkat/L</td><td>0.36±0.02</td><td>0.38±0.01</td><td>0.40±0.03</td><td>0.66±0.02*/**</td></tr><tr><td>Urine creatinine, mmol/l</td><td>2.64±0.37</td><td>2.11±0.18</td><td>2.26±0.18</td><td>3.54±0.32*</td></tr><tr><td>GFR, ml/day</td><td>410.4±28.5</td><td>380.5±18.6</td><td>389.4±14.3</td><td>315.6±8.2*/**</td></tr></tbody></table></table-wrap><p>The data obtained show that in the state of general anesthesia using the 1st mode of gas mixture delivery, no statistically significant changes in key blood biochemical parameters or renal function indices were observed in animals. Only single trend-based changes were observed. This indicates the good condition of organs and systems, such as the liver, heart, and urinary system, after general anesthesia. This pattern demonstrates good tolerability of the anesthetic protocol used.</p><p>At the same time, when using the 2nd mode of gas mixture delivery, a significant decrease in the blood glucose level by 21.7% (p &lt; 0.05), an increase in ALT by 1.7 times (p &lt; 0.05), an increase in blood creatinine by 31.8% (p &lt; 0.05), urine creatinine — by 1.6 times (p &lt; 0.05) and a corresponding decrease in the GFR by 18.8% (p &lt; 0.05) were observed. All of the above indicates damage to some of the organs and systems of animals as a result of general anesthesia. First of all, it is worth to note the suppression of renal function, as evidenced by the GFR indicator. The activation of cytolysis, which may occur due to liver damage caused by inhalation anesthetic is also worth noting. A drop in glycemia also fits into the overall picture and indicates exhaustion of animals exposed to anesthesia.</p><p>This picture correlates with the laboratory observations. The animals were in a very deep phase of anesthesia (approximately 3–4), characterised by pronounced depression of respiratory system, with infrequent and deep breathing, and depression of cardiovascular system. EEG indices were also depressed. On the whole, this indicates poor tolerability of the second mode of anesthesia with the chosen duration time. This effect of isoflurane can be explained by stagnation of the gas mixture in the inhalation chamber due to the lack of forced gas removal, decrease of air content in the chamber, and consequent decrease of partial pressure of oxygen. This ultimately has led to deep hypoxia in the animals and, consequently, to deterioration of organ and tissue resistance to this mode of anesthesia.</p><p>Discussion and Conclusion. The obtained results demonstrate the high efficacy of the developed device—an inhalation chamber for rats connected to an anesthesia machine—for laboratory monitoring animals’ condition during general anesthesia induced by inhalation. Analysis of the results reveals a significant correlation between animals’ electrophysiological, functional, and biochemical parameters, which together enable a comprehensive assessment of the anesthesia protocol safety.</p><p>Thus, the proposed inhalation chamber enables monitoring general anesthesia using electrophysiological methods that are objective, sensitive, highly informative, and correlate well with the results of biochemical and functional studies in animals. This approach has good perspective for  practical implementation in the experimental study of veterinary drugs, and may contribute to improving the quality of research results, as well as may facilitate the work of researchers.</p></body><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Бетшарт-Вольфенсбергер Р., Стекольников А.А., Племяшов К.В., Нечаев А.Ю. Общая анестезия и эвтаназия в ветеринарии: учебное пособие. Санкт Петербург: Проспект Науки, 2024. 376 с.</mixed-citation><mixed-citation xml:lang="en">Betshart-Wolfensberger R, Stekolnikov AA, Plemyashov KV, Nechaev AYu. General Anesthesia and Euthanasia In Veterinary Medicine: A Textbook. Saint Petersburg: Prospect Nauki; 2024. 376 p. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Bille C, Auvigne V, Bomassi E, Durieux P, Libermann S, Rattez E. An Evidence-Based Medicine Approach to Small Animal Anaesthetic Mortality in a Referral Practice: The Influence of Initiating three Recommendations on Subsequent Anaesthetic Deaths. Veterinary Anaesthesia and Analgesia. 2014;41(3):249–258. https://doi.org/10.1111/vaa.12116</mixed-citation><mixed-citation xml:lang="en">Bille C, Auvigne V, Bomassi E, Durieux P, Libermann S, Rattez E. An Evidence-Based Medicine Approach to Small Animal Anaesthetic Mortality in a Referral Practice: The Influence of Initiating three Recommendations on Subsequent Anaesthetic Deaths. Veterinary Anaesthesia and Analgesia. 2014;41(3):249–258. https://doi.org/10.1111/vaa.12116</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Baetge CL, Matthews NS. Anesthesia and Analgesia for Geriatric Veterinary Patients. Veterinary Clinics of North America: Small Animal Practice. 2012;42(4):643–653. https://doi.org/10.1016/j.cvsm.2012.05.001</mixed-citation><mixed-citation xml:lang="en">Baetge CL, Matthews NS. Anesthesia and Analgesia for Geriatric Veterinary Patients. Veterinary Clinics of North America: Small Animal Practice. 2012;42(4):643–653. https://doi.org/10.1016/j.cvsm.2012.05.001</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Bille C, Auvigne V, Libermann S, Bomassi E, Durieux P, Rattez E. Risk of Anaesthetic Mortality in Dogs and Cats: An Observational Cohort Study of 3546 Cases. Veterinary Anaesthesia and Analgesia. 2012:39(1):59–68. https://doi:10.1111/j.1467-2995.2011.00686.x</mixed-citation><mixed-citation xml:lang="en">Bille C, Auvigne V, Libermann S, Bomassi E, Durieux P, Rattez E. Risk of Anaesthetic Mortality in Dogs and Cats: An Observational Cohort Study of 3546 Cases. Veterinary Anaesthesia and Analgesia. 2012:39(1):59–68. https://doi:10.1111/j.1467-2995.2011.00686.x</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Grubb T, Sager J, Gaynor JS, Montgomery E, Parker JA, Shafford H, Tearney C. 2020 AAHA Anesthesia and Monitoring Guidelines for Dogs and Cats. Journal of American Animal Hospital Association. 2020;56(2):59–82. https://doi.org/10.5326/jaaha-ms-7055</mixed-citation><mixed-citation xml:lang="en">Grubb T, Sager J, Gaynor JS, Montgomery E, Parker JA, Shafford H, Tearney C. 2020 AAHA Anesthesia and Monitoring Guidelines for Dogs and Cats. Journal of American Animal Hospital Association. 2020;56(2):59–82. https://doi.org/10.5326/jaaha-ms-7055</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Pinho RH, Nasr-Esfahani M, Pang DSJ. Medication Errors in Veterinary Anesthesia: A Literature Review. Veterinary Anaesthesia and Analgesia. 2024;51(3):203–226. https://doi.org/10.1016/j.vaa.2024.01.003</mixed-citation><mixed-citation xml:lang="en">Pinho RH, Nasr-Esfahani M, Pang DSJ. Medication Errors in Veterinary Anesthesia: A Literature Review. Veteri-nary Anaesthesia and Analgesia. 2024;51(3):203–226. https://doi.org/10.1016/j.vaa.2024.01.003</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Jones H, Robson K, Maddox T, Alderson B. Incidence of and Risk Factors for Poor Recovery Quality in Dogs Recovering from General Anaesthesia-A Prospective Case Control Study. Veterinary Anaesthesia and Analgesia. 2024;51(3):227–234. https://doi.org/10.1016/j.vaa.2023.12.002</mixed-citation><mixed-citation xml:lang="en">Jones H, Robson K, Maddox T, Alderson B. Incidence of and Risk Factors for Poor Recovery Quality in Dogs Recovering from General Anaesthesia-A Prospective Case Control Study. Veterinary Anaesthesia and Analgesia. 2024;51(3):227–234. https://doi.org/10.1016/j.vaa.2023.12.002</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Varkoulis K, Savvas I, Anagnostou T, Kazakos G, Pavlidou K. A Retrospective Study on Canine and Feline Mortality during Anaesthesia at a University Clinic in Greece. Animals. 2023;13(15):2486. https://doi.org/10.3390/ani13152486</mixed-citation><mixed-citation xml:lang="en">Varkoulis K, Savvas I, Anagnostou T, Kazakos G, Pavlidou K. A Retrospective Study on Canine and Feline Mortality during Anaesthesia at a University Clinic in Greece. Animals. 2023;13(15):2486. https://doi.org/10.3390/ani13152486</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Brodbelt DC, Blissitt KJ, Hammond RA, Neath PJ, Young LE, Pfeiffer DU, Pfeiffer DU. The Risk of Death: The Confidential Enquiry into Perioperative Small Animal Fatalities. Veterinary Anaesthesia and Analgesia. 2008;35(5):365–373. https://doi.org/10.1111/j.1467-2995.2008.00397.x</mixed-citation><mixed-citation xml:lang="en">Brodbelt DC, Blissitt KJ, Hammond RA, Neath PJ, Young LE, Pfeiffer DU, Pfeiffer DU. The Risk of Death: The Confidential Enquiry into Perioperative Small Animal Fatalities. Veterinary Anaesthesia and Analgesia. 2008;35(5):365–373. https://doi.org/10.1111/j.1467-2995.2008.00397.x</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Reiser K, Schroers M, Reese S, Meyer-Lindenberg A. Gängige veterinärmedizinische Praxis in der Kleinti-eranästhesie – eine Onlineumfrage unter Kleintierpraktikern in Europa [Common Veterinary Practice in Small Animal Anesthesia — An Online Survey among Small Animal Practitioners in Europe]. Tierärztliche Praxis Ausgabe K: Kleintiere Heimtiere. 2021;49(5):325–334. https://doi.org/10.1055/a-1543-5167</mixed-citation><mixed-citation xml:lang="en">Reiser K, Schroers M, Reese S, Meyer-Lindenberg A. Gängige veterinärmedizinische Praxis in der Kleintieranästhesie – eine Onlineumfrage unter Kleintierpraktikern in Europa [Common Veterinary Practice in Small Animal Anesthesia — An Online Survey among Small Animal Practitioners in Europe]. Tierärztliche Praxis Ausgabe K: Kleintiere Heimtiere. 2021;49(5):325–334. https://doi.org/10.1055/a-1543-5167</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Truchetti G, Otis C, Brisville AC, Beauchamp G, Pang D, Troncy E. Management of Veterinary Anesthesia in Small Animals: A Survey of Current Practice in Quebec. PLoS One. 2020;15(1):e0227204. https://doi.org/10.1371/journal.pone.0227204</mixed-citation><mixed-citation xml:lang="en">Truchetti G, Otis C, Brisville AC, Beauchamp G, Pang D, Troncy E. Management of Veterinary Anesthesia in Small Animals: A Survey of Current Practice in Quebec. PLoS One. 2020;15(1):e0227204. https://doi.org/10.1371/journal.pone.0227204</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Bennett K, Lewis K. Sedation and Anesthesia in Rodents. Vetterinary Clinics of North America Exotic Animal Practice. 2022;25(1):211–255. https://doi.org/10.1016/j.cvex.2021.08.013</mixed-citation><mixed-citation xml:lang="en">Bennett K, Lewis K. Sedation and Anesthesia in Rodents. Vetterinary Clinics of North America Exotic Animal Practice. 2022;25(1):211–255. https://doi.org/10.1016/j.cvex.2021.08.013</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ 33216-2014. Руководство по содержанию и уходу за лабораторными животными. Правила содержания и ухода за лабораторными грызунами и кроликами. Издание официальное. Москва: Стандартинформ; 2016. 16 с.</mixed-citation><mixed-citation xml:lang="en">GOST 33216-2014. Guidelines for the Care and Maintenance of Laboratory Animals. Rules for the Care and Mainte-nance of Laboratory Rodents and Rabbits. Official Edition. Moscow: Standartinform; 2016. 16 p. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Kalkan KK, Kekecoglu M. Ethical Principles and Rules in Experimental Animal Studies: A Comprehensive Review. Duzce Medical Journal. 2024;26(S1):1–13. https://doi.org/10.18678/dtfd.1497730</mixed-citation><mixed-citation xml:lang="en">Kalkan KK, Kekecoglu M. Ethical Principles and Rules in Experimental Animal Studies: A Comprehensive Re-view. Duzce Medical Journal. 2024;26(S1):1–13. https://doi.org/10.18678/dtfd.1497730</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Directive 2010/63/EU of the European Parliament and of the Council of 22 September 2010 on the Protection of Animals Used for Scientific Purposes. Official Journal of the European Union. 2010; Document 32010L0063. URL: https://eur-lex.europa.eu/eli/dir/2010/63/oj</mixed-citation><mixed-citation xml:lang="en">Directive 2010/63/EU of the European Parliament and of the Council of 22 September 2010 on the Protection of Animals Used for Scientific Purposes. Official Journal of the European Union. 2010; Document 32010L0063. URL: https://eur-lex.europa.eu/eli/dir/2010/63/oj</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Flecknell P. Laboratory Animal Anesthesia. 4th Ed. London: Academic Press, 2015. 350р.</mixed-citation><mixed-citation xml:lang="en">Flecknell P. Laboratory Animal Anesthesia. 4th Ed. London: Academic Press, 2015. 350р.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Лычева Н.А., Макарова М.Н., Макаров В.Г., Рыбакова А.В. Влияние различных видов анестезии на параметры электрокардиограммы у крыс. Лабораторные животные для научных исследований. 2018;2:16–23. https://10.29296/2618723X-2018-02-02</mixed-citation><mixed-citation xml:lang="en">Lycheva NA, Makarova MN, Makarov VG, Rybakova AV. Effect of Different Species of Anesthesia on Electrocardiogram Parameters in Rats. Laboratory Animals for Science. 2018;2:16–23. (In Russ.). https://10.29296/2618723X-2018-02-02</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Caracciolo SF, Bertran GC, Arini PD. Electrocardiography in Wistar Rat Experimental Model: Analysis and Char-acterization. Sistema Nacional de Repositorios Digitales. 2018. URL: https://repositoriosdigitales.min-cyt.gob.ar/vufind/Record/CONICETDig_3359662e317b0cc411c85e6d4108a7da</mixed-citation><mixed-citation xml:lang="en">Caracciolo SF, Bertran GC, Arini PD. Electrocardiography in Wistar Rat Experimental Model: Analysis and Characterization. Sistema Nacional de Repositorios Digitales. 2018. URL: https://repositoriosdigitales.min-cyt.gob.ar/vufind/Record/CONICETDig_3359662e317b0cc411c85e6d4108a7da</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Allen PS, Dell’Italia LJ, Esvelt M, Conte ML, Cadillac JM, Myers DD. Cardiovascular Research. In: Suckow MA, Hankenson FC, Wilson RP, Foley PL (Eds). The Laboratory Rat. 3rd Ed: Elsevier; 2020. P. 927–965. https://doi.org/10.1016/B978-0-12-814338-4.00025-8</mixed-citation><mixed-citation xml:lang="en">Allen PS, Dell’Italia LJ, Esvelt M, Conte ML, Cadillac JM, Myers DD. Cardiovascular Research. In: Suckow MA, Hankenson FC, Wilson RP, Foley PL (Eds). The Laboratory Rat. 3rd Ed: Elsevier; 2020. P. 927–965. https://doi.org/10.1016/B978-0-12-814338-4.00025-8</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Каркищенко Н.Н., Грачев С.В. Руководство по лабораторным животным и альтернативным моделям в биомедицинских технологиях. Москва; 2010. 344 с.</mixed-citation><mixed-citation xml:lang="en">Karkischenko NN, Grachev SV. Handbook on Laboratory Animals and Alternative Models in Biomedical Technologies. Moscow; 2010. 344 p. (In Russ.).</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Rifai N, Horvath AR, Wittwer CT. Tietz Fundamentals of Clinical Chemistry and Molecular Diagnostics. 8th Ed. St. Louis: Elsevier Health Science; 2019. 1062 p.</mixed-citation><mixed-citation xml:lang="en">Rifai N, Horvath AR, Wittwer CT. Tietz Fundamentals of Clinical Chemistry and Molecular Diagnostics. 8th Ed. St. Louis: Elsevier Health Science; 2019. 1062 p.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Koeppen BM, Stanton BA. Renal Physiology. 6th Ed. Philadelphia: Elsevier; 2019. 248 р.</mixed-citation><mixed-citation xml:lang="en">Koeppen BM, Stanton BA. Renal Physiology. 6th Ed. Philadelphia: Elsevier; 2019. 248 р.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Islam MA, Al-Shiha A. Foundations of Biostatistics. Singapore: Springer; 2018. 474 р.</mixed-citation><mixed-citation xml:lang="en">Islam MA, Al-Shiha A. Foundations of Biostatistics. Singapore: Springer; 2018. 474 р.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Pokhrel LR, Grady KD. Risk Assessment of Occupational Exposure to Anesthesia Isoflurane in the Hospital and Veterinary Settings. Science of the Total Environment. 2021;783:146894. https://doi.org/10.1016/j.sci-totenv.2021.146894</mixed-citation><mixed-citation xml:lang="en">Pokhrel LR, Grady KD. Risk Assessment of Occupational Exposure to Anesthesia Isoflurane in the Hospital and Veterinary Settings. Science of the Total Environment. 2021;783:146894. https://doi.org/10.1016/j.sci-totenv.2021.146894</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
